14 resultados para Ophthalmic Optics

em Helda - Digital Repository of University of Helsinki


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glaucoma is a group of progressive optic neuropathies causing irreversible blindness if not diagnosed and treated in the early state of progression. Disease is often, but not always, associated with increased intraocular pressure (IOP), which is also the most important risk factor for glaucoma. Ophthlamic timolol preparations have been used for decades to lower increased intraocular pressure (IOP). Timolol is locally well tolerated but may cause e.g. cardiovascular and pulmonary adverse effects due to systemic absorption. It has been reported that approximately 80% of a topically administered eye drop is systemically absorbed. However, only limited information is available on timolol metabolism in the liver or especially in the human eye. The aim of this work was to investigate metabolism of timolol in human liver and human ocular tissues. The expression of drug metabolizing cytochrome P450 (CYP) enzymes in the human ciliary epithelial cells was studied. The metabolism of timolol and the interaction potential of timolol with other commercially available medicines were investigated in vitro using different liver preparations. The absorption of timolol to the aqueous humor from two commercially available products: 0.1% eye gel and 0.5% eye drops and the presence of timolol metabolites in the aqueous humor were investigated in a clinical trial. Timolol was confirmed to be metabolized mainly by CYP2D6 as previously suggested. Potent CYP2D6 inhibitors especially fluoxetine, paroxetine and quinidine inhibited the metabolism of timolol. The inhibition may be of clinical significance in patients using ophthalmic timolol products. CYP1A1 and CYP1B1 mRNAs were expressed in the human ciliary epithelial cells. CYP1B1 was also expressed at protein level and the expression was strongly induced by a known potent CYP1B1 inducer 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). The CYP1B1 induction is suggested to be mediated by aryl hydrocarbon receptor (AHR). Low levels of CYP2D6 mRNA splice variants were expressed in the human ciliary epithelial cells and very low levels of timolol metabolites were detected in the human aqueous humor. It seems that negligible amount of CYP2D6 protein is expressed in the human ocular tissues. Timolol 0.1% eye gel leads to aqueous humor concentration high enough to achieve therapeutic effect. Inter-individual variation in concentrations is low and intraocular as well as systemic safety can be increased when using this product with lower timolol concentration instead of timolol 0.5% eye drops.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In Finland, the incidence of type 1 diabetes mellitus (T1DM) is the highest in the world, and it continues to increase steadily. No effective preventative interventions exist either for individuals at high risk or for the population as a whole. In addition to problems with daily lifelong insulin replacement therapy, T1DM patients with long-lasting disease suffer from various diabetes related complications. The complications can lead to severe impairments and reductions in functional capacity and quality of life and in the worst case they can be fatal. Longitudinal studies on the costs of T1DM are extremely rare, especially in Finland. Typically, in these studies, distinctions between the various types of diabetes have not been made, and costs have not been calculated separately for the sexes. Aims. The aim of this study was to describe inpatient hospital care and costs of inpatient care in a cohort of 5,166 T1DM patients by sex during 1973-1998 in Finland. Inpatient care and costs of care due to T1DM without complications, due to T1DM with complications and due to other causes were calculated separately. Material and Methods. The study population consisted of all Finnish T1DM patients diagnosed before the age of 18 years between January 1st in 1965 and December 31st in 1979 and derived from the Finnish population based T1DM register (N=5,120 in 1979 and N=4,701 in 1997). Data on hospitalisations were obtained from the Finnish Hospital Discharge Register. Results. In the early stages of T1DM, the majority of the use of inpatient care was due to the treatment of T1DM without complications. There were enormous increases in the use of inpatient care for certain complications when T1DM lasted longer (from 9.5 years to 16.5 years). For women, the yearly number of bed-days for renal complications increased 4.8-fold, for peripheral vascular disease 4.3-fold and for ophthalmic complications 2.5-fold. For men, the corresponding increases were as follows: 5-fold, 6.9-fold and 2.5-fold. The yearly bed-days for glaucoma increased 8-fold, nephropathy 7-fold and microangiopathy 6-fold in the total population. During these 7 years, the yearly numbers of bed-days for T1DM without complications dropped dramatically. The length of stay in inpatient care decreased notably, but hospital visits became more frequent when the length of duration of T1DM increased from 9.5 years to 16.5 years. The costs of treatments due to complications increased when T1DM lasted longer. Costs due to inpatient care of complications in the cohort 2.5-folded as duration of T1DM increased from 9.5 years to 16.5 years, while the total costs of inpatient care in the cohort dropped by 22% due to an 80% decrease in the costs of care of T1DM without complications. Treating complications of female patients was more expensive than treating complications of men when T1DM had lasted 9.5 years; the mean annual costs for inpatient care of a female diabetic (any cause) were 1,642 , and the yearly costs of care of complications were 237 . The corresponding yearly mean costs for a male patient were 1,198 and 167 . Treating complications of female patients was more expensive than that of male patients also when the duration of diabetes was 16.5 years, although the difference in average annual costs between sexes was somewhat smaller. Conclusions. In the early phases of T1DM, the treatment of T1DM without complications causes a considerable amount of hospital bed-days. The use of inpatient care due to complications of T1DM strongly increases with ageing of patients. The economic burden of inpatient care of T1DM is substantial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Refractive errors, especially myopia, seem to increase worldwide. Concurrently, the number of surgical refractive corrections has increased rapidly, with several million procedures performed annually. However, excimer laser surgery was introduced after a limited number of studies done with animals and to date there still are only few long-term follow-up studies of the results. The present thesis aims to evaluate the safety and functional outcome of, as well as to quantify the cellular changes and remodelling in the human cornea after, photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK). These procedures are the two most common laser surgical refractive methods. In Study I, myopic ophthalmic residents at Helsinki University Eye Hospital underwent a refractive correction by PRK. Five patients were followed up for 6 months to assess their subjective experience in hospital work and their performance in car driving simulator and in other visuomotor functions. Corneal morphological changes were assessed by in vivo confocal microscopy (ivCM). Study II comprised 14 patients who had undergone a PRK operation in 1993-1994. Visual acuity was examined and ivCM examinations performed 5 years postoperatively. In Study III 15 patients received LASIK refractive correction for moderate to high myopia (-6 - -12 D). Their corneal recovery was followed by ivCM for 2 years. Diffuse lamellar keratitis (DLK) is a common but variable complication of LASIK. Yet, its aetiology remains unknown. In Study IV we examined six patients who had developed DLK as a consequence of formation of an intraoperative or post-LASIK epithelial defect, to assess the corneal and conjunctival inflammatory reaction. In the whole series, the mean refractive correction was -6.46 diopters. The best spectacle corrected visual acuity (BSCVA) improved in 30 % of patients, whereas in four patients BSCVA decreased slightly. The mean achieved refraction was 0.35 D undercorrected. After PRK, the stromal scar formation was highest at 2 to 3 months postoperatively and subsequently decreased. At 5 years increased reflectivity in the subepithelial stroma was observed in all patients. Interestingly, no Bowman s layer was detected in any patient. Subbasal nerve fiber bundle(snfb) regeneration could be observed already at 2 months in 2 patients after PRK. After 5 years, all corneas presented with snfb, the density of which, however, was still lower than in control corneas. LASIK induced a hypocellular area on both sides of the flap interface. A decrease of the most anterior keratocyte density was also observed. In the corneas that developed DLK, inflammatory cell-type objects were present in the flap interface in half of the patients. The other patients presented only with keratocyte activation and highly reflective extracellular matrix. These changes resolved completely with medication and time. Snfb regeneration was first detected at one month post-LASIK, but still after two years the density of snfb, however, was only 64 % of the preoperative values. The performance of ophthalmological examinations and microsurgery without spectacles was easier postoperatively, which was appreciated by the residents. Both PRK and LASIK showed moderate to good accuracy and high safety. In terms of visual perception and subjective evaluation, few patients stated any complaints in the whole series of studies. Instead, the majority of patients experienced a marked improvement in everyday life and work performance. PRK and LASIK have shown similar results, with good long term morphological healing. It seems evident that, even without the benefit of over-20-year follow-up results, these procedures are sufficiently safe and accurate for refractive corrections and corneal reshaping.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Visual acuities at the time of referral and on the day before surgery were compared in 124 patients operated on for cataract in Vaasa Central Hospital, Finland. Preoperative visual acuity and the occurrence of ocular and general disease were compared in samples of consecutive cataract extractions performed in 1982, 1985, 1990, 1995 and 2000 in two hospitals in the Vaasa region in Finland. The repeatability and standard deviation of random measurement error in visual acuity and refractive error determination in a clinical environment in cataractous, pseudophakic and healthy eyes were estimated by re-examining visual acuity and refractive error of patients referred to cataract surgery or consultation by ophthalmic professionals. Altogether 99 eyes of 99 persons (41 cataractous, 36 pseudophakic and 22 healthy eyes) with a visual acuity range of Snellen 0.3 to 1.3 (0.52 to -0.11 logMAR) were examined. During an average waiting time of 13 months, visual acuity in the study eye decreased from 0.68 logMAR to 0.96 logMAR (from 0.2 to 0.1 in Snellen decimal values). The average decrease in vision was 0.27 logMAR per year. In the fastest quartile, visual acuity change per year was 0.75 logMAR, and in the second fastest 0.29 logMAR, the third and fourth quartiles were virtually unaffected. From 1982 to 2000, the incidence of cataract surgery increased from 1.0 to 7.2 operations per 1000 inhabitants per year in the Vaasa region. The average preoperative visual acuity in the operated eye increased by 0.85 logMAR (in decimal values from 0.03to 0.2) and in the better eye 0.27 logMAR (in decimal values from 0.23 to 0.43) over this period. The proportion of patients profoundly visually handicapped (VA in the better eye <0.1) before the operation fell from 15% to 4%, and that of patients less profoundly visually handicapped (VA in the better eye 0.1 to <0.3) from 47% to 15%. The repeatability visual acuity measurement estimated as a coefficient of repeatability for all 99 eyes was ±0.18 logMAR, and the standard deviation of measurement error was 0.06 logMAR. Eyes with the lowest visual acuity (0.3-0.45) had the largest variability, the coefficient of repeatability values being ±0.24 logMAR and eyes with a visual acuity of 0.7 or better had the smallest, ±0.12 logMAR. The repeatability of refractive error measurement was studied in the same patient material as the repeatability of visual acuity. Differences between measurements 1 and 2 were calculated as three-dimensional vector values and spherical equivalents and expressed by coefficients of repeatability. Coefficients of repeatability for all eyes for vertical, torsional and horisontal vectors were ±0.74D, ±0.34D and ±0.93D, respectively, and for spherical equivalent for all eyes ±0.74D. Eyes with lower visual acuity (0.3-0.45) had larger variability in vector and spherical equivalent values (±1.14), but the difference between visual acuity groups was not statistically significant. The difference in the mean defocus equivalent between measurements 1 and 2 was, however, significantly greater in the lower visual acuity group. If a change of ±0.5D (measured in defocus equivalents) is accepted as a basis for change of spectacles for eyes with good vision, the basis for eyes in the visual acuity range of 0.3 - 0.65 would be ±1D. Differences in repeated visual acuity measurements are partly explained by errors in refractive error measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prevalence and the causes of childhood visual impairment in Finland during the 1970s and the 1980s were investigated, with special attention to risk factors and further prevention of visual impairment in children. The primary data on children with visual impairment were obtained from the Finnish Register of Visual Impairment, one of the patient registers kept up by the National Research and Development Centre for Welfare and Health (Stakes). The data were supplemented from other registers in Stakes and from patient records of the children in Finnish central hospitals. Visual impairment had been registered in 556 children from a population of 1,138,326 children between ages 0-17, born from 1972 through 1989. The age-specific prevalence of registered visual impairment was 49/100,000 in total. Of them, 23/100,000 were blind children and 11/100,000 were children born prematurely. Boys were impaired more often and more severely than girls. Congenital malformations (52%), systemic diseases (48%), and multiple impairments (50%) were common. The main ophthalmic groups of visual impairment were retinal diseases (35%), ocular malformations (29%), and neuro-ophthalmological disorders (29%). Optic nerve atrophy was the most common diagnosis of visual impairment (22%), followed by congenital cataract (11%), retinopathy of prematurity (10%), and cerebral visual impairment (8%). Genetic factors (42%) were the most common etiologies of visual impairment, followed by prenatal (30%) and perinatal (21%) factors. The highest rates of blindness were seen in cerebral visual impairment (83%) and retinopathy of prematurity (82%). Retinopathy of prematurity had developed in the children born at a gestational age of 32 weeks or earlier. Significant risks for visual impairment were found in the association with preterm births, prenatal infections, birth asphyxia, neonatal respiratory difficulties, mechanical ventilation lasting over two weeks, and hyperbilirubinemia. A rise in blind and multi-impaired children was seen during the study period, associating with increases in the survival of preterm infants with extremely low birth weight. The incidence of visual impairment in children born prematurely was seven times higher than in children born at full term. A reliable profile of childhood visual impairment was obtained. The importance of highly qualified antenatal, neonatal, and ophthalmological care was clearly proved. The risks associated with pre- and perinatal disorders during pregnancy must be emphasized, e.g. the risks associated with maternal infections and the use of tobacco, alcohol, and drugs during pregnancy. Obvious needs for gene therapies and other new treatments for hereditary diseases were also proved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first observations of solar X-rays date back to late 1940 s. In order to observe solar X-rays the instruments have to be lifted above the Earth s atmosphere, since all high energy radiation from the space is almost totally attenuated by it. This is a good thing for all living creatures, but bad for X-ray astronomers. Detectors observing X-ray emission from space must be placed on-board satellites, which makes this particular discipline of astronomy technologically and operationally demanding, as well as very expensive. In this thesis, I have focused on detectors dedicated to observing solar X-rays in the energy range 1-20 keV. The purpose of these detectors was to measure solar X-rays simultaneously with another X-ray spectrometer measuring fluorescence X-ray emission from the Moon surface. The X-ray fluorescence emission is induced by the primary solar X-rays. If the elemental abundances on the Moon were to be determined with fluorescence analysis methods, the shape and intensity of the simultaneous solar X-ray spectrum must be known. The aim of this thesis is to describe the characterization and operation of our X-ray instruments on-board two Moon missions, SMART-1 and Chandrayaan-1. Also the independent solar science performance of these two almost similar X-ray spectrometers is described. These detectors have the following two features in common. Firstly, the primary detection element is made of a single crystal silicon diode. Secondly, the field of view is circular and very large. The data obtained from these detectors are spectra with a 16 second time resolution. Before launching an instrument into space, its performance must be characterized by ground calibrations. The basic operation of these detectors and their ground calibrations are described in detail. Two C-flares are analyzed as examples for introducing the spectral fitting process. The first flare analysis shows the fit of a single spectrum of the C1-flare obtained during the peak phase. The other analysis example shows how to derive the time evolution of fluxes, emission measures (EM) and temperatures through the whole single C4 flare with the time resolution of 16 s. The preparatory data analysis procedures are also introduced in detail. These are required in spectral fittings of the data. A new solar monitor design equipped with a concentrator optics and a moderate size of field of view is also introduced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accelerator mass spectrometry (AMS) is an ultrasensitive technique for measuring the concentration of a single isotope. The electric and magnetic fields of an electrostatic accelerator system are used to filter out other isotopes from the ion beam. The high velocity means that molecules can be destroyed and removed from the measurement background. As a result, concentrations down to one atom in 10^16 atoms are measurable. This thesis describes the construction of the new AMS system in the Accelerator Laboratory of the University of Helsinki. The system is described in detail along with the relevant ion optics. System performance and some of the 14C measurements done with the system are described. In a second part of the thesis, a novel statistical model for the analysis of AMS data is presented. Bayesian methods are used in order to make the best use of the available information. In the new model, instrumental drift is modelled with a continuous first-order autoregressive process. This enables rigorous normalization to standards measured at different times. The Poisson statistical nature of a 14C measurement is also taken into account properly, so that uncertainty estimates are much more stable. It is shown that, overall, the new model improves both the accuracy and the precision of AMS measurements. In particular, the results can be improved for samples with very low 14C concentrations or measured only a few times.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article discusses the physics programme of the TOTEM experiment at the LHC. A new special beam optics with beta* = 90 m, enabling the measurements of the total cross-section, elastic pp scattering and diffractive phenomena already at early LHC runs, is explained. For this and the various other TOTEM running scenarios, the acceptances of the leading proton detectors and of the forward tracking stations for some physics processes are described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The status of the TOTEM experiment is described as well as the prospects for the measurements in the early LHC runs. The primary goal of TOTEM is the measurement of the total p-p cross section, using a method independent of the luminosity. A final accuracy of 1% is ex- pected with dedicated β∗ = 1540 m runs, while at the beginning a 5% resolution is achievable with a β∗ = 90 m optics. Accordingly to the running scenarios TOTEM will be able to measure the elastic scattering in a wide range of t and to study the cross-sections and the topologies of diffractive events. In a later stage, physics studies will be extended to low-x and forward physics collaborating with CMS as a whole experimental apparatus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Uveal melanoma (UM) is the second most common primary intraocular cancer worldwide. It is a relatively rare cancer, but still the second most common type of primary malignant melanoma in humans. UM is a slowly growing tumor, and gives rise to distant metastasis mainly to the liver via the bloodstream. About 40% of patients with UM die of metastatic disease within 10 years of diagnosis, irrespective of the type of treatment. During the last decade, two main lines of research have aimed to achieve enhanced understanding of the metastasis process and accurate prognosis of patients with UM. One emphasizes the characteristics of tumor cells, particularly their nucleoli, and markers of proliferation, and the other the characteristics of tumor blood vessels. Of several morphometric measurements, the mean diameter of the ten largest nucleoli (MLN) has become the most widely applied. A large MLN has consistently been associated with high likelihood of dying from UM. Blood vessels are of paramount importance in metastasis of UM. Different extravascular matrix patterns can be seen in UM, like loops and networks. This presence is associated with death from metastatic melanoma. However, the density of microvessels is also of prognostic importance. This study was undertaken to help understanding some histopathological factors which might contribute to developing metastasis in UM patients. Factors which could be related to tumor progression to metastasis disease, namely nucleolar size, MLN, microvascular density (MVD), cell proliferation, and The Insulin-like Growth Factor 1 Receptor(IGF-1R), were investigated. The primary aim of this thesis was to study the relationship between prognostic factors such as tumor cell nucleolar size, proliferation, extravascular matrix patterns, and dissemination of UM, and to assess to what extent there is a relationship to metastasis. The secondary goal was to develop a multivariate model which includes MLN and cell proliferation in addition to MVD, and which would fit better with population-based, melanoma-related survival data than previous models. I studied 167 patients with UM, who developed metastasis even after a very long time following removal of the eye, metastatic disease was the main cause of death, as documented in the Finnish Cancer Registry and on death certificates. Using an independent population-based data set, it was confirmed that MLN and extravascular matrix loops and networks were unrelated, independent predictors of survival in UM. Also, it has been found that multivariate models including MVD in addition to MLN fitted significantly better with survival data than models which excluded MVD. This supports the idea that both the characteristics of the blood vessels and the cells are important, and the future direction would be to look for the gene expression profile, whether it is associated more with MVD or MLN. The former relates to the host response to the tumor and may not be as tightly associated with the gene expression profile, yet most likely involved in the process of hematogenous metastasis. Because fresh tumor material is needed for reliable genetic analysis, such analysis could not be performed Although noninvasive detection of certain extravascular matrix patterns is now technically possible,in managing patients with UM, this study and tumor genetics suggest that such noninvasive methods will not fully capture the process of clinical metastasis. Progress in resection and biopsy techniques is likely in the near future to result in fresh material for the ophthalmic pathologist to correlate angiographic data, histopathological characteristics such as MLN, and genetic data. This study supported the theory that tumors containing epithelioid cells grow faster and have poorer prognosis when studied by cell proliferation in UM based on Ki-67 immunoreactivity. Cell proliferation index fitted best with the survival data when combined with MVD, MLN, and presence of epithelioid cells. Analogous with the finding that high MVD in primary UM is associated with shorter time to metastasis than low MVD, high MVD in hepatic metastasis tends to be associated with shorter survival after diagnosis of metastasis. Because the liver is the main organ for metastasis from UM, growth factors largely produced in the liver hepatocyte growth factor, epidermal growth factor and insulin-like growth factor-1 (IGF-1) together with their receptors may have a role in the homing and survival of metastatic cells. Therefore the association between immunoreactivity for IGF-1R in primary UM and metastatic death was studied. It was found that immunoreactivity for IGF-IR did not independently predict metastasis from primary UM in my series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilises direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially non-homogenous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wavelength tuning and stability characteristics of a singly resonant continuous-wave optical parametric oscillator (cw OPO) in the proximity of signal-idler degeneracy have been studied. The OPO is made singly resonant by using a Bragg grating as a spectral filter in the OPO cavity. The signal-idler frequency difference can be tuned from 0.5 to 7 THz, which makes the OPO suitable for cw THz generation by optical heterodyning. The operation of the OPO within this singly-resonant regime is characterized by a strong self-stabilization effect. A gradual transition to an unstable, doubly-resonant regime is observed for a signal-idler detuning smaller than ~ 0.5 THz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple method for absolute frequency measurements of molecular transitions in the mid-infrared region is reported. The method is based on a cw singly-resonant optical parametric oscillator (SRO), which is tunable from 3.2 to 3.45 µm. The mid- infrared frequency of the SRO is referenced to an optical frequency comb through its pump and signal beams. Sub-Doppler spectroscopy and absolute frequency measurement of the P(7) transition of the ν3 band of CH4 are demonstrated.